help button home button
AJRCCM
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by ZAKYNTHINOS, S. G.
Right arrow Articles by ROUSSOS, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by ZAKYNTHINOS, S. G.
Right arrow Articles by ROUSSOS, C.

Am. J. Respir. Crit. Care Med., Volume 162, Number 5, November 2000, 1633-1640

Contribution of Expiratory Muscle Pressure to Dynamic Intrinsic Positive End-Expiratory Pressure
Validation Using the Campbell Diagram

SPYROS G. ZAKYNTHINOS, THEODOROS VASSILAKOPOULOS, EPAMINONDAS ZAKYNTHINOS, ANTONIS MAVROMMATIS, and CHARIS ROUSSOS

Department of Critical Care and Pulmonary Services, Athens University Medical School, Evangelismos Hospital, Athens, Greece

In spontaneously breathing (SB) patients expiratory muscle contraction leads to an overestimation of dynamic intrinsic PEEP (PEEPi,dyn). To quantify this overestimation, PEEPi,dyn measured with the esophageal balloon technique was corrected for the increase in Pga over the course of expiration (Pga,exp rise), for the whole decay of Pga during inspiration (Pga,total decay) or for the part of Pga decay restricted between the onset of inspiratory effort and the point of zero flow (Pga,zf decay). Corrections were compared with the reference PEEPi,dyn (PEEPi,dyn ref ), calculated by using the Campbell diagram. In 15 ventilator-dependent, SB, and actively expiring patients, we found that the difference PEEPi,dyn - Pga,total decay (mean ± SD, 5.7 ± 1.9 cm H2O) was quite similar to PEEPi,dyn ref (5.3 ± 1.9 cm H2O). Their mean difference was 0.37 cm H2O with limits of agreement -0.09 to 0.83 cm H2O, indicating strong agreement between these methods. PEEPi,dyn - Pga,exp rise (6.0 ± 2.1 cm H2O) was also similar to PEEPi,dyn ref. Their mean difference was 0.72 cm H2O with limits of agreement -1.69 to 3.13 cm H2O, indicating good agreement. In contrast, mean difference of PEEPi,dyn - Pga,zf decay and PEEPi,dyn ref was 3.14 cm H2O with limits of agreement -0.46 to 6.74 cm H2O, indicating lack of agreement. The error in measurement due to the subtraction of Pga,zf decay from PEEPi,dyn (i.e., [PEEPi,dyn - Pga,zf decay] - PEEPi,dyn ref ) was proportional to the intensity of expiratory muscle contraction, as expressed by the Pga,exp rise (r = 0.903, p < 0.001). We conclude that in actively expiring patients an adequate correction of PEEPi,dyn for the overestimation caused by expiratory muscle contraction can be made by subtracting either Pga,total decay or Pga,exp rise from PEEPi,dyn, the former achieving the best performance.




This article has been cited by other articles:


Home page
J Intensive Care MedHome page
Hongyan Liang, E. L. Daugherty, D. Taichman, J. Hansen-Flaschen, and B. D. Fuchs
Recognition and Importance of Forced Exhalation on the Measurement of Intraabdominal Pressure: A Subgroup Analysis From a Prospective Cohort Study on the Incidence of Abdominal Compartment Syndrome in Medical Patients
J Intensive Care Med, July 1, 2008; 23(4): 268 - 274.
[Abstract] [PDF]


Home page
J. Appl. Physiol.Home page
J. A. Guenette, I. Vogiatzis, S. Zakynthinos, D. Athanasopoulos, M. Koskolou, S. Golemati, M. Vasilopoulou, H. E. Wagner, C. Roussos, P. D. Wagner, et al.
Human respiratory muscle blood flow measured by near-infrared spectroscopy and indocyanine green
J Appl Physiol, April 1, 2008; 104(4): 1202 - 1210.
[Abstract] [Full Text] [PDF]


Home page
J Intensive Care MedHome page
E. L. Daugherty, Hongyan Liang, D. Taichman, J. Hansen-Flaschen, and B. D. Fuchs
Abdominal Compartment Syndrome Is Common in Medical Intensive Care Unit Patients Receiving Large-Volume Resuscitation
J Intensive Care Med, September 1, 2007; 22(5): 294 - 299.
[Abstract] [PDF]


Home page
J. Physiol.Home page
F. J. O'Donoghue, P. G. Catcheside, D. J. Eckert, and R. D. McEvoy
Changes in respiration in NREM sleep in hypercapnic chronic obstructive pulmonary disease
J. Physiol., September 1, 2004; 559(2): 663 - 673.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
A C Davidson
The pulmonary physician in critical care * 11: Critical care management of respiratory failure resulting from COPD
Thorax, December 1, 2002; 57(12): 1079 - 1084.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
M Gorini, G Villella, R Ginanni, A Augustynen, D Tozzi, and A Corrado
Effect of assist negative pressure ventilation by microprocessor based iron lung on breathing effort
Thorax, March 1, 2002; 57(3): 258 - 262.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. J. TOBIN
Critical Care Medicine in AJRCCM 2000
Am. J. Respir. Crit. Care Med., October 15, 2001; 164(8): 1347 - 1361.
[Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
M. GORINI, A. CORRADO, G. VILLELLA, R. GINANNI, A. AUGUSTYNEN, and D. TOZZI
Physiologic Effects of Negative Pressure Ventilation in Acute Exacerbation of Chronic Obstructive Pulmonary Disease
Am. J. Respir. Crit. Care Med., June 1, 2001; 163(7): 1614 - 1618.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Respir. Crit. Care Med.Home page
S. G. Zakynthinos and T. Vassilakopoulos
CONTRIBUTION OF EXPIRATORY MUSCLE PRESSURE TO DYNAMIC INTRINSIC POSITIVE END-EXPIRATORY PRESSURE
Am. J. Respir. Crit. Care Med., April 1, 2001; 163(5): 1278a - 1279.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Proc. Am. Thorac. Soc. Am. J. Respir. Cell Mol. Biol.
Copyright © 2000 American Thoracic Society
  ATS State of the Art Course 2008